FLAMEX 20 TYPE MSZ 1X0.5

Description

Description

Standards

  • Product
    EN 45545-2 (HL3)
  • Test
    EN 50200; EN 50305; EN 50306; IEC 60331-2

 

FLAMEX® Fire Resistant control wires TYPE EN 50306-2 maintain circuit integrity in case of fire (according to EN 50200 for 120 minutes) and are fire retardant, low smoke and halogenfree safisfying performance requirements of EN 45545-2 HL3. In addition, FLAMEX® cables withstand the tough working conditions of rolling stock (oil, ozone, temperature variations, etc.).

 

DESIGN

1. Conductor
Flexible stranded tinned copper

2. Insulation
Mineral tape as fire barrier
Thin wall halogen-free cross-linked material acc. EN 50306-2
Colour: white

Example of marking:  FLAMEX 239 - EDE 2PN299 - TYPE EN 50306-2 - EN 50200 - 300 V - 1x0.5 - M - week/year - batch number
 

 

FIRE SAFETY STANDARDS

FLAMEX® Fire Resistant control wires are conform to EN 45545-2.

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 5 x outer cable diameter
    • For installation and occasional movements: 10 x outer cable diameter

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible stranded
Insulation
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2
Insulation colour
White

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
0,5 mm²
Stranding (No./mm)
Conductor diameter (mm)
0.95
Minimum cable diameter
1,7 mm
Maximum cable diameter
2 mm
Approximate weight
7,5 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
300 / 300 V
Max. DC resistance of the conductor at 20°C
40,1 Ohm/km

Usage characteristics

Usage characteristics

Fire resistant
-
Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 105 °C
Maximum operating temperature
105 °C
Overload maximum core temperature
125 °C
Chemical resistance
Excellent
Fire load
0,009 kWh/m

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close