FLAMEX EN 50382-2 3600V 120 FXZ 120°C

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

FLAMEX® EN 50382-2 3600V FXZ power cables are designed with extra flexible conductors and reinforced with textile braid to be used as a jumper cable between vehicles. Able to withstand higher operating temperatures, these silicone-based cables allow to save cable weight.

DESIGN

1. Conductor
Extra Flexible class 6 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class
Separator: Unweaved tape 

2. Insulation
Cross-linked silicone type EI 111, according to EN 50382-1 with an embedded polyester reinforcement
Colour: black outer layer

Examples of marking:
FLAMEX SI - EN 50382-2  - 3600 V - cross-section mm² - FXZ - class temperature (120°C) - NEXANS 279 - week/year  
FLAMEX SI - DTREN 150028 - EN 50382-2  - 3600 V - cross-section mm² - FXZ - class temperature (120°C) - NEXANS 279 - week/year

 

FIRE SAFETY

FLAMEX® EN 50382-2 3600V FXZ power cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Extra-flexible class 6
Insulation
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
120 mm²
Conductor diameter
14,2 mm
Nominal outer diameter
20,8 mm
Minimum outer diameter
20,5 mm
Maximum outer diameter
24,3 mm
Approximate weight
1480 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
3.6 / 6 (7.2) kV

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Max. conductor temperature in service
120 °C
Overload maximum core temperature
140 °C
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close