FLAMEX® EN 50382-2 FF

Products

FLAMEX SI EN 50382-2 1800V 120 FF 120°C

Nexans ref. 10260585

  • Packaging: m (1000m)
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 150 FF 120°C

Nexans ref. 10198408

  • Packaging: m (1000m)
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 185 FF 120°C

Nexans ref. 10260584

  • Packaging: m (1000m)
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 240 FF 120°C

Nexans ref. 10217649

  • Packaging: m (1000m)
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 50 FF 120°C

Nexans ref. 10260587

  • Packaging: m (1000m)
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 70 FF 120°C

Nexans ref. 10260586

  • Packaging: m (1000m)
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 95 FF 120°C

Nexans ref. 10198407

  • Packaging: m (1000m)
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 3600V 120 FF 120°C

Nexans ref. 10211471

  • Packaging: m (1000m)
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 150 FF 120°C

Nexans ref. 10211472

  • Packaging: m (1000m)
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 185 FF 120°C

Nexans ref. 10211473

  • Packaging: m (1000m)
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 240 FF 120°C

Nexans ref. 10211474

  • Packaging: m (1000m)
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 50 FF 120°C

Nexans ref. 10211468

  • Packaging: m (1000m)
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 70 FF 120°C

Nexans ref. 10211469

  • Packaging: m (1000m)
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 95 FF 120°C

Nexans ref. 10211470

  • Packaging: m (1000m)
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

DESIGN

 

1. Conductor
Flexible class 5 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class
Separator: Unweaved tape

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1

3. Outer sheath
Cross-linked silicone type EM 107 according to EN 50382-1
Colour: black outer layer

Example of marking: FLAMEX SI - EN 50382-2  - Voltage rate (1800V or 3600V) - cross-section mm² - FF - temperature class (120°C or 150°C) - LYNXEO 279 - week/year

GUIDE TO USE

 

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible class 5
Insulation
High temperature silicone
Outer sheath
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Max. conductor temperature in service
120 °C
Overload maximum core temperature
140 °C
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close