FLAMEX® EN 50382-2 F

Products

FLAMEX SI EN 50382-2 1800V 10F 120°C

Nexans ref. 10195311

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 10 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 10F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 10 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 120F 120°C

Nexans ref. 10207187

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 120F 150°C

Nexans ref. 10227161

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 150F 120°C

Nexans ref. 10198300

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 150F 150°C

Nexans ref. 10261513

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 16F 120°C

Nexans ref. 10211402

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 16 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 16F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 16 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 185F 120°C

Nexans ref. 10211464

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 185F 150°C

Nexans ref. 10269713

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 2.5F 120°C

Nexans ref. 10195310

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 2,5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 2.5F 150°C

Nexans ref. 10261509

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 2,5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 240F 120°C

Nexans ref. 10211465

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 240F 150°C

Nexans ref. 10227159

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 25F 120°C

Nexans ref. 10207155

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 25F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 300F 120°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 300 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 300F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 300 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 35F 120°C

Nexans ref. 10211403

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 35F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 4F 120°C

Nexans ref. 10203262

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 4 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 4F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 4 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 50F 120°C

Nexans ref. 10207186

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 50F 150°C

Nexans ref. 10261511

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 6F 120°C

Nexans ref. 10211401

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 6F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 70F 120°C

Nexans ref. 10195312

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 70F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 95F 120°C

Nexans ref. 10195313

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 95F 150°C

Nexans ref. 10261512

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 6F 150°C

Nexans ref. 10270404

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 6 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 10F 120°C

Nexans ref. 10195796

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 10 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 10F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 10 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 120F 120°C

Nexans ref. 10179833

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 120F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 150F 120°C

Nexans ref. 10179834

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 150F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 16F 120°C

Nexans ref. 10256165

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 16 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 16F 150°C

Nexans ref. 10267838

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 16 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 185F 120°C

Nexans ref. 10179835

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 185F 150°C

Nexans ref. 10227160

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 2.5F 120°C

Nexans ref. 10211467

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 2,5 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 2.5F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 2,5 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 240F 120°C

Nexans ref. 10179836

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 240F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 25F 120°C

Nexans ref. 10195124

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 25F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 300F 120°C

Nexans ref. 10281085

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 300F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 35F 120°C

Nexans ref. 10241573

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 35F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 4F 120°C

Nexans ref. 10191664

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 4 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 4F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 4 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 50F 120°C

Nexans ref. 10179832

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 50F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 6F 120°C

Nexans ref. 10211466

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 6 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 70F 120°C

Nexans ref. 10191170

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 70F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 95F 120°C

Nexans ref. 10191194

  • Coletaj: Drum (1000m)
  • Conductor: Tin plated copper
  • Diametru conductor: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 95F 150°C

Nexans ref.

  • Coletaj: Drum (1000m)
  • Conductor: Plain copper
  • Diametru conductor: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

DESIGN

 

1. Conductor
Flexible class 5 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class

Separator: Unweaved tape

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Colour: black outer layer

Example of marking: FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - F - temperature class (120°C or 150°C) - LYNXEO 279 - week/year

 

GUIDE TO USE

 

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

Characteristics

Characteristics

Constructie

Constructie

Conductor flexibility
Flexible class 5
Izolatie
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Alte caracteristici

Alte caracteristici

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close