FLAMEX SI EN 50382-2 Type FFXS 1.8/3 kV 1x185 150°C

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

DESIGN

 

1. Conductor
Extra flexible class 6 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Separator: Unweaved tape

3. Screen
Tinned copper wire braid
Separator: Unweaved tape

4. Outer sheath
Cross-linked silicone type EM 107 according to EN 50382-1
Colour: black outer layer

Examples of marking: 
FLAMEX SI - EN 50382-2  - Voltage rate (1800V or 3600V) - cross-section mm² - FFXS - temperature class (120°C or 150°C) - Manufacturing n° -  NEXANS 279 - week/year
DTREN 150068 - EN 50382-2 - 1800V - cross-section mm² - FFXS - temperature class (120°C) - Manufacturing n° - NEXANS 279 -  week/year

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Plain copper
Conductor flexibility
Extra-flexible class 6
Insulation
High temperature silicone
Screen
Tinned copper braid
Outer sheath
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
185 mm²
Conductor diameter
18.2 mm
Braid section
12.5 mm²
Nominal outer diameter
27.7 mm
Minimum outer diameter
26.3 mm
Maximum outer diameter
29.6 mm
Approximate weight
2064 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
1.8 / 3 (3.6) kV

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
150 °C
Overload maximum core temperature
170 °C
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close