FLAMEX® EN 50382-2 F

Produkty

FLAMEX SI EN 50382-2 1800V 10F 120°C

Nexans ref. 10195311

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 10F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 120F 120°C

Nexans ref. 10207187

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 120F 150°C

Nexans ref. 10227161

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 150F 120°C

Nexans ref. 10198300

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 150F 150°C

Nexans ref. 10261513

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 16F 120°C

Nexans ref. 10211402

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 16F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 185F 120°C

Nexans ref. 10211464

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 185F 150°C

Nexans ref. 10269713

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 2.5F 120°C

Nexans ref. 10195310

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 2,5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 2.5F 150°C

Nexans ref. 10261509

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 2,5 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 240F 120°C

Nexans ref. 10211465

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 240F 150°C

Nexans ref. 10227159

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 25F 120°C

Nexans ref. 10207155

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 25F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 300F 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 300F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 35F 120°C

Nexans ref. 10211403

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 35F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 4F 120°C

Nexans ref. 10203262

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 4F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 50F 120°C

Nexans ref. 10207186

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 50F 150°C

Nexans ref. 10261511

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 6F 120°C

Nexans ref. 10211401

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 6F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 70F 120°C

Nexans ref. 10195312

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 70F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 95F 120°C

Nexans ref. 10195313

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 95F 150°C

Nexans ref. 10261512

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 6F 150°C

Nexans ref. 10270404

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 10F 120°C

Nexans ref. 10195796

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 10F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 10 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 120F 120°C

Nexans ref. 10179833

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 120F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 150F 120°C

Nexans ref. 10179834

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 150F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 16F 120°C

Nexans ref. 10256165

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 16F 150°C

Nexans ref. 10267838

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 16 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 185F 120°C

Nexans ref. 10179835

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 185F 150°C

Nexans ref. 10227160

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 2.5F 120°C

Nexans ref. 10211467

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 2,5 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 2.5F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 2,5 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 240F 120°C

Nexans ref. 10179836

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 240F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 25F 120°C

Nexans ref. 10195124

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 25F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 300F 120°C

Nexans ref. 10281085

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 300F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 35F 120°C

Nexans ref. 10241573

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 35F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 4F 120°C

Nexans ref. 10191664

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 4F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 4 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 50F 120°C

Nexans ref. 10179832

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 50F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 6F 120°C

Nexans ref. 10211466

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 6 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 70F 120°C

Nexans ref. 10191170

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 70F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 95F 120°C

Nexans ref. 10191194

  • Packaging: Drum (1000m)
  • Material jádra: Tin plated copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 95F 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Material jádra: Plain copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

Popis

Popis

Normy

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

DESIGN

 

1. Conductor
Flexible class 5 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class

Separator: Unweaved tape

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Colour: black outer layer

Example of marking: FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - F - temperature class (120°C or 150°C) - LYNXEO 279 - week/year

 

GUIDE TO USE

 

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

Charakteristika

Charakteristika

Konstrukční charakteristika

Konstrukční charakteristika

Conductor flexibility
Flexible class 5
Isolace
High temperature silicone
Bezhalogenové
EN 60754-1 & EN 60684-2

Charakteristika použití

Charakteristika použití

Samozhášivost
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Hustota dýmu
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Chemická odolnost
Good

Zdroje

Zdroje

Kontaktujte nás

Témata, o kterých si přejete získat více informací:

Požadovaná pole*

Zkontrolujte prosím svůj údaj a zkuste to znovu

E-mailová adresa musí obsahovat jediný znak @

Ochránce osobních údajů

Máte právo vznést námitku proti zpracování svých osobních údajů a/nebo jejich použití pro přímý marketing nebo komerční účely

Děkujeme vám!

Děkujeme, že jste nás kontaktovali. Brzy se s vámi spojíme.

Chyba

Došlo k chybě. Zkuste prosím aggain.

Zavřít