FLAMEX SI EN 50382-2 1800V 120 FX 150°C

Popis

Popis

Normy

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

FLAMEX® EN 50382-2 FX power cables are designed with extra flexible conductors for easier installation. Able to withstand higher operating temperatures, these silicone-based cables allow to save cable weight.

DESIGN

1. Conductor
Extra flexible class 6 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class
Separator: Unweaved tape

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Colour: black outer layer

Example of marking: FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - FX - temperature class (150°C) - LYNXEO 279 - week/year

 

FIRE SAFETY

FLAMEX® EN 50382-2 FX power cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

 

Charakteristika

Charakteristika

Konstrukční charakteristika

Konstrukční charakteristika

Material jádra
Plain copper
Conductor flexibility
Extra-flexible class 6
Isolace
High temperature silicone
Bezhalogenové
EN 60754-1 & EN 60684-2

Rozměrová charakteristika

Rozměrová charakteristika

Conductor cross-section
120 mm²
Conductor diameter
14,2 mm
Nominal outer diameter
20,0 mm
Minimum outer diameter
18,6 mm
Maximum outer diameter
21,7 mm
Approximate weight
1212 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
1.8 / 3 (3.6) kV

Charakteristika použití

Charakteristika použití

Samozhášivost
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Hustota dýmu
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Max. conductor temperature in service
150 °C
Overload maximum core temperature
170 °C
Chemická odolnost
Good

Zdroje

Zdroje

Dokumentace

FLAMEX SI type F png — 9.5 kB

Kontaktujte nás

Témata, o kterých si přejete získat více informací:

Požadovaná pole*

Zkontrolujte prosím svůj údaj a zkuste to znovu

E-mailová adresa musí obsahovat jediný znak @

Ochránce osobních údajů

Máte právo vznést námitku proti zpracování svých osobních údajů a/nebo jejich použití pro přímý marketing nebo komerční účely

Děkujeme vám!

Děkujeme, že jste nás kontaktovali. Brzy se s vámi spojíme.

Chyba

Došlo k chybě. Zkuste prosím aggain.

Zavřít